Functionality |
ISO 13850 |
ISO 13850 defines the characteristics and requirements for a traditional electromechanical E-STOP switch. The MR387 Sensor/Controller integrates the definition of purpose and functionality only. |
ISO 13849 |
Category 2 for MR380/MR387 E-STOP Sensor/Controller System |
Functional Safety |
Consult Declaration of Conformity for additional F.S. information |
Classification |
MR387 Sensor/Controller System = Category 2 per ISO 13849-1 |
MTTFd |
4.14 E+06 hours (473.1 years) |
Performance Level |
PL=c |
Safety Integrity Level |
SIL=1 |
Functional States |
MR380 Controller Output States |
Normal RESET (Up Position) |
Red LED is OFF
Digital 5V and 24V Outputs=HI
Relay NC contacts=Closed, Relay NO contacts=Open
|
ACTIVATED (Down Position)
Broken Fiber, Loss of Optical Signal, or Controller Failure
|
Red LED is ON
Digital 5V and 24V Outputs=LOW
Relay NC contacts=Open, Relay NO contacts=Closed
|
Optical Interface |
Interface |
Duplex LC for pigtailed sensors, MR387-X-YY where YY is pigtail length in meters ODVA IP-LC connector receptacle, MR387-X-D00 sensors in housing |
Insertion Loss |
MR387-2-XX, 2.5 dB (2 dB Typical), LC-Duplex Pigtail, 62.5/125μm OM-1 MM Fiber
MR387-3-XX, 5.0 dB (3 dB Typical), LC-Duplex Pigtail, 9/125μm OS-1 SM Fiber
MR387-5-XX, 3.5 dB (3 dB Typical), LC-Duplex Pigtail, 50/125μm OM-2 MM Fiber
Consult Application Note AN118 for guidance on determining system loss budget and maximum distance
|
Explosive Atmospheres |
Inherently Safe, Simple Mechanical Device |
EX Classification |
Inherently safe, simple mechanical device when used with MR380 Controller
IECEx Test Report GB/CML/ExTR 16.0105.00/00
|
ATEX |
EPL Mb/Gb/Gc/Db/Dc |
EAEU/GOST |
EPL Mb/Gb/Gc/Db/Dc |
IEC Ex |
EPL Mb/Gb/Gc/Db/Dc |
North America |
Exempt, non-electrical |
Environmental |
Temperature/Humidity |
-40°C to +65°C (-40°F to +150°F), 0-95% RH, Non-Condensing |
Ingress Protection |
Pigtailed Version=IP61, Panel Mount Housing=IP65 |
Mechanical |
Housing |
Aluminum body, anodized finish |
Durability |
100,000 operations min. |
Physical |
Housing Dimension |
Consult Mechanical Reference Drawing |
Mounting |
Consult Mechanical Reference Drawing |
Unit Weight |
Sensor with 5 meter pigtail, 240 g (8.5 oz) |